

- #ANIME STUDIO DEBUT 9 SXSTRACE TOOL UPDATE#
- #ANIME STUDIO DEBUT 9 SXSTRACE TOOL CODE#
- #ANIME STUDIO DEBUT 9 SXSTRACE TOOL WINDOWS#

You can go to C:\Windows\WinSxs folder and manually verify this dependent assembly is there or not. Here we are clear with what we are missing. Please use sxstrace.exe for detailed diagnosis." Dependent Assembly, processorArchitecture="x86", publicKeyToken="1fc8b3b9a1e18e3b", type="win32", version="2.8" could not be found. "Activation context generation failed for “ DataViewer.dll". Go to event viewer and check for entry with sidebyside.
#ANIME STUDIO DEBUT 9 SXSTRACE TOOL WINDOWS#
Since the error message itself is saying “Please check windows event viewer for further information”. Now we need to think about the solution for this. Side by side error will come irrespective of OS, if reference assembly is missing from Sxs folder. Since most of the experiences for this issue are in Vista, initially I thought it is only in Vista machine.
#ANIME STUDIO DEBUT 9 SXSTRACE TOOL CODE#
(Project Properties -> C/C++ -> Code Generation -> Runtime Library -> use/MT or /MTd depends on your current configuration.) This may work, but it is not the solution for this issue. Change your project settings to not use the runtime library, but this will make the output EXE bigger. We have to check if it is possible to resolve with project settings because EXE will run in debug build and fails to start in release build. If the side-by-side manager finds a dependence on version 6.0 stated in a manifest, that version is loaded to run with the application. For Windows XP, version 5.0 of Comctl32.DLL is the system default. If there is no relevant manifest, the system loads the default version of the assembly. When an application calls to load the DLL, the side-by-side manager determines whether the application has a version dependence described in a manifest. In the preceding example shown in above picture, both Comctl32.DLL version 6.0 and Comctl32.DLL version 5.0 are in the side-by-side assembly cache and available to applications.
#ANIME STUDIO DEBUT 9 SXSTRACE TOOL UPDATE#
For example, an application can be updated to use a side-by-side assembly that includes an update without having to reinstall the application. Applications and administrators can update assembly configuration on either a global or per-application configuration basis after deployment.Side-by-side assembly sharing enables multiple versions of COM or Windows assemblies to run at the same time.Side-by-side assemblies reduce the possibility of DLL version conflicts.Developers are encouraged to use side-by-side assemblies to create isolated applications, and to update existing applications into isolated applications for the following reasons: In many cases, it is possible to update existing applications to use side-by-side assemblies without having to change the application code. These are described in the assembly manifest. What is Side by Side Configuration?Ī side-by-side assembly contains a collection of resources-a group of DLLs, Windows classes, COM servers, type libraries, or interfaces-that are always provided to applications together. Side-by-side technology is also known as WinSxS or SxS. E.g.: the C Runtime Library assembly contains three DLLs- msvcr80.dll, msvcm80.dll and msvcp80.dll - and is used by applications when they are built using functions from the CRT library. Side by side configuration is a trick for versioning files, in which multiple versions of a file are installed in a single machine. While starting an application, we may get an error “This application has failed to start because its side by side configuration is incorrect”. Most of the developers using assemblies in their application may have faced this issue.
